![]() If transmitting tags to an In-Sight OPC Server, the following requirements must also be met:Īre the data values that are transferred, may contain any 8-bit or 2-byte character. ![]() For instance, you cannot have one tag as "test" and the other as "Test". ![]() There cannot be a duplicate Tag Name within No spaces or non-English language characters may be used.Ī minimum of 1 character and a maximum of 127 characters.īe cell names or have the form of cell names (e.g., B2 or B22222). Use the following characters: A-Z, a-z, 0-9 and the underscore "_"Ĭharacter. The spreadsheet cell may have only one Tag associated with it.After enabling the In EasyView checkbox, use the EasyView Settings dialog to customize how the data is displayed on VisionView. In EasyView: When checked, the symbolic tag is added to the EasyView.Use the Audit Message Settings dialog to configure audit message settings for the active vision system and to specify the IP address and TCP/IP port of the audit message server. Audit Message: When checked, any changes made to the cell's contents (e.g., changes made to the cell's formula or interactive control value) automatically generates and sends an audit message via TCP/IP, which can be imported into an audit message server in a compliance software system.If the target cell does contain one of these functions and you are receiving an error, verify that the value you are attempting to write does not exceed any limits of the function, such as minimum value, maximum value or string length. To the In-Sight OPC Classic Server and to third-party OPC Classic clients. The target cell does not contain one of these functions, it will be read-only For the OPC Classic Server, only EditFloat, EditInt and EditString cells are writable via OPC.If the target cell does not contain one of these functions, it will be read-only to the In-Sight OPC UA Server and to third-party OPC UA clients. For OPC UA, only Checkbox, EditFloat, EditInt, EditString and ListBox spreadsheet cells are writable.Vision System/SensorĪ cell in the spreadsheet that contains information that you want to transmit, or a cell that already contains a symbolic tag.Ī symbolic tag, the shortcut menu option will be Edit The In-Sight OPC UA Server and In-Sight OPC Classic Server are supported on the following models. In this case, do not use a cell name or the form of a cell name for a symbolic tag name. However, when the Symbolic Tag Editor dialog is opened from In-Sight Explorer, a symbolic tag name error is displayed in cell B3. For example, when the Extended Native Mode command EV SetCellName(B3,"A32767") is issued, the command will be executed successfully and the symbolic tag name "A32767" will be inserted in cell B3. In-Sight Explorer may recognize a valid symbolic tag name as invalid when the symbolic tag name is in the form of a cell name with the value greater than 32766.
0 Comments
Leave a Reply. |